This guide is to help on how to flash CDM(before
8.1.1.01) when using WW/JB after 8.1.1.01.
Issue/problem:
After WW boot up in chassis (6014/NEC), it not able goto Act/Stdby and at
the same time rsys-ipmitool not able to flash/read CDM (error message device ID
not found)
Solution:
1. Stop CMM (command: "cmm stop")
2. Manually input / tell IPMC what chassis are you using now with command
below:
i) NEC (CMM will reboot after execute command below)
rsys-ipmitool raw 0x2e 0xc0 0xf1 0x10 0 5
ii) 6014/6016
rsys-ipmitool raw 0x2e 0xc0 0xf1 0x10 0 6
3. Once WW rebooted, login again and stop the cmm.
4. In CMM1, Verify you can read the CDM now by executing command
rsys-ipmitool -t 0x20 -m 0x10 fru read 1 FILENAME.bin
5. If can read, then proceed with flashing new CDM in CMM1
rsys-ipmitool -t 0x20 -m 0x10 fru write 1 NEWCDM.bin
6. Reboot/power cycle whole chassis and wait the WW/JB boot up and go into
Act/Stdby state.
No comments: